Characteristics: | | Display | : LCD 3,5/6(max.6000), digit height 14mm | Sampling | : 3x/sec. | DC Voltage | : 0,1mV...600mV/ 6V/ 60V/ 600V/1000V | Accuracy | : ±(0,5%+3digits) | AC Voltage | : 0,1mV...600mV/ 6V/ 60V/ 600V/1000V(40Hz-500Hz) | Accuracy | : ±(1,0%+ 3digits) | DC current | : 0,1µA... 600µA/6000µA/60mA/600mA/6A/10A | Accuracy | : ±(1,5%+3digits) | AC current | : 0,1µA... 600µA/6000µA/ 60mA/600mA/6A/10A (40Hz...200Hz) | Accuracy | : ±(1,5%+3digits) | Resistance | : 0,1Ω... 600Ω/6kΩ/60kΩ/600kΩ/6MΩ/60MΩ | Accuracy | : ±(1,0%+2digits) | Continuity test | : buzzer for R<50Ω | Diode test | : test current: 1mA; test voltage: 1,5V DC | Capacitance | : 0,01nF...60nF/600nF/6µF/60µF/300µF | Accuracy | : ±(3,0%+5digits) | Frequency | : 0,01Hz...100Hz/1kHz/10kHz/100kHz/1MHz | Accuracy | : ±(2,0%+3 digits) | Temperature | : -55°C...1000°C | Accuracy | : ±(2,0%+1°C) | Duty Cycle | : 0,1% to 99,9% | Dimensions | : 180 x 85 x 40 mm | Weight | : approx. 310 g | Supply voltage | : battery 9V type 6F22 | Safety | : 1000V CAT. II and 600V CAT. III | Pollution degree | : 2 |
Standard equipment: - set of test leads - set of test leads for capacitance measurement - temperature probe with ball tip, terminated by 4 mm banana plugs - software PC-Link on CD - optocable for USB
|